X1-SMART (SINGLE-PHASE)
|
|||
Model
|
X1-6.0-T-D
X1-6.0-T-N
|
X1-7.0-T-D
X1-7.0-T-N
|
X1-8.0-T-D
X1-8.0-T-N
|
DC INPUT
|
|||
Max. PV array input power [Wp]
|
9000
|
10500
|
12000
|
Max. PV input voltage [V]
|
550
|
||
Startup voltage [V]
|
100
|
||
Nominal input voltage [V]
|
360
|
||
MPP tracker voltage range [V]
|
100~530
|
||
No. of MPP trackers/Strings per MPP tracker
|
2(1/2)
|
||
Max. input current(input A/input B) [A]
|
12/24
|
||
Max. short circuit current(input A/input B) [A]
|
14/28
|
||
AC OUTPUT
|
|||
Nominal AC output power [W]
|
6000
|
7000
|
8000
|
Nominal AC output current [A]
|
26
|
30
|
36.7
|
Max. AC output apparent power [VA]
|
6600
|
7700
|
8800
|
Max. AC output current [A]
|
28.7
|
33.5
|
38.3
|
Nominal AC voltage [V]
|
220V/230/240,160~285
|
||
Nominal grid frequency/Grid frequency range [Hz]
|
50/60; ±5
|
||
Displacement power factor
|
0.8 leading~0.8 lagging
|
||
THDi (rated power) [%]
|
<3
|
||
SYSTEM DATA
|
|||
Max. effiffifficiency [%]
|
97.40
|
||
Euro. effiffifficiency [%]
|
96.80
|
||
Standby consumption [W] @Night
|
<1
|
||
Ingress protection
|
IP65
|
||
Operating temperature range [OC]
|
-25~60 (derating at 45)
|
||
Max. operation altitude [m]
|
≤2000
|
||
Humidity [%]
|
0~100 (non-condensing)
|
||
Typical noise emission [dB]
|
<40
|
||
Storage temperature [OC]
|
-25~60
|
||
Dimensions(W×H×D) [mm
|
401*450*190
|
||
Weight [kg]
|
22
|
||
Cooling concept
|
Nature cooling
|
||
Communication interfaces
|
RS485/USB/DRM/CT/(Optional: Pocket WiFi/LAN)
|
||
PROTECTION
|
|||
Over/under voltage protection
|
YES
|
||
DC isolation protection
|
YES
|
||
Monitoring ground fault protection
|
YES
|
||
Grid monitoring
|
YES
|
||
DC injection monitoring
|
YES
|
||
Back feed current monitoring
|
YES
|
||
Residual current detection
|
YES
|
||
Anti-islanding protection
|
YES
|
||
Over temp protection
|
YES
|
||
STANDARD
|
|||
Safety
|
IEC/EN 62109-1/-2
|
||
EMC
|
EN61000-6-1/2/3/4;EN61000-3-2/3/11/12
|
||
Certifification
|
AS4777.2/EN 61000-3-2/EN 61000-3-3/EN 61000-3-11/EN 61000-3-12/EN 61000-6-1/EN 61000-6-2/EN 61000-6-3
|